9 Troubleshooting
9-1-4
Other Display List
Name
Disable selection dis-
play
No data
I/O all OFF display
Communications not es-
tablished display
Measuring capacitor ca-
pacity
RUN command display
at insufficient voltage
levels
Data overflow display
Parameter disable se-
lection display
Password protection
status display
STO state display
Run/operation complete
display
During jogging operation Indicates that the inverter is in jogging operation
9-26
Description
Displayed when the operation selection of the con-
trol mode to handle data selected within Operator
Display Selection during Run (E43) is disabled.
Displayed when the data assigned in the parame-
ter and submenu does not exist.
Displayed when all points are OFF in the I/O check
terminal I/O binary display.
Displayed when communications with the inverter
have not been established, such as at power sup-
ply ON, etc.
Displayed during measurement of capacitors at a
primary voltage drop.
Displayed when at or below the insufficient voltage
level and there is a RUN command when monitor-
ing inverter output results from amongst LED moni-
tors.
Covered LED monitor items:
Speed monitor, output current, consumption
power, torque detection value, output voltage,
motor output, load rate, PID output
Non-covered LED monitor items:
PID process, PID feedback, analog monitor
Displayed when the display coefficient is set too
high, when selecting rotation speed, load speed,
and line speed in the LED monitor and run monitor,
and the display speed is 100000 or higher (at dis-
play data overflow).
Displayed when disable is selected while setting
parameters.
Displays the password protection status by lighting
or blinking the least significant digit dot during dis-
play of the main menu or lower level parameters.
Lit: Password protection enabled
Blinking: Password is temporarily not protected
Off: Password protection disabled
Displays the STO state when the functional safety
STO input terminal is turned OFF when there is a
RUN command in the operation mode.
Displayed at operation completion of timer opera-
tion or transport operation in the operation mode.
Additionally, this is displayed at operation comple-
tion of auto-tuning.
status in the operation mode.
Digital operator display
Lit or blinking
Least significant dot lit or blink-
ing
(Display example)
M1 Series Standard Type User's Manual (I669)