Programming Devices
Compatible Programming
Devices
Note
Functions Supported by
Programming Devices
Settings
Programming Device
mode (recognized by
Programming Console (Programming Con-
sole bus)
CX-Programmer
Peripheral bus
54
The following Programming Devices can be used.
• Programming Consoles
• CX-Programmer Ver. 1.2 or later (register the PLC model as a CQM1H-
CPU61.)
1. The Customizable Counter Unit cannot be used with CX-Programmer Ver.
1.1 or earlier.
2. The SYSMAC-CPT or SYSMAC Support Software cannot be used.
The functions available when using a Programming Device with the Customiz-
able Counter Unit are the same as when using one with a CPU Unit with the
following exceptions.
• PLC Setup functions
• Reading the error log
• PLC clock
• Forced set/reset of the PLC
• Data trace
• Reading the cycle time
• PLC information display
Note Before using the CX-Programmer, refer to the appendix, Precautions in Using
the CX-Programmer.
The following settings are required when using a Programming Device.
Programming Device Connection Switch
You must turn ON the Programming Device connection switch on the front of
the Unit before connecting a Programming Device to the peripheral port. It will
not be possible to connect to the Programming Device if this switch is turned
OFF. (Turn OFF this switch, however, to prevent malfunctions due to opera-
tional errors.)
Programming Device connection
switch
Set to ON:
TOOL
Set to OFF:
TOOL
Unit Setup Area
When connecting a Programming Device to the peripheral port, depending on
the type of Programming Device, the serial communications mode, and com-
munications conditions used, the Unit Setup Area (DM 6650 to DM 6651) set-
tings may or may not be necessary. This is shown in the following table.
Serial
Communications
communications
conditions
Unit)
---
9,600 bps
Other than above
Connection enabled
(The switch must be turned ON to use a
ON
OFF
Programming Device.)
Connection disabled
ON
OFF
(Turn OFF the switch to prevent
operational errors.)
Unit Setup Area
(DM 6650 to
DM 6651)
Settings not required
Settings not required
Set in DM 6650 to
DM 6651 (baud rate
only)
Section 3-4
Programming Device
Setting in CX-
Programmer
---
Set to the same com-
munications condi-
tions.