Details
6-2-6
Timer/Counter Area
6-2-7
DM Area
Read/Write Words in
DM Area
Area type
Read/write portion of DM Area (for
general-purpose data)
Other Parts of DM Area
Area
Addresses
Error Log Area
DM 6144 to
DM 6199
This area is used to manage the TIM, TIMH(15), TMHH(––), CNT, and
CNTR(12) instructions. The same numbers are used for timers and counters;
do not use the same number twice even for different instructions.
If TIM/CNT number is designated for word data, it will access the present
value (PV); if it is used for bit data, it will access the Completion Flag for the
timer/counter.
The Completion Flag turns ON when the PV of the timer/counter that is being
used goes to 0.
Interrupt processing is not performed for TIMH(15), i.e., timing processing is
performed only when the instructions is executed. If the cycle time is longer
than 10 ms, counting may not be reliable.
For details on using these instructions, refer to the individual explanations in
the Customizable Counter Units Programming Manual (W384).
This area is used in word units. The DM Area is contained in I/O memory (i.e.,
areas that can be freely read and written from the ladder program) and areas
to which functions are allocated.
The words in this area do not have any special functions and can be used as
required in programming. They can be read and written to using instructions
or a Programming Device.
Addresses
Instructions
Reading
DM 0000 to
OK
DM 6143
Error Log Area
When a fatal or non-fatal error occurs in the Customizable Counter Unit, the
Special I/O Unit error code and the error contents are stored automatically in
this area along with the time and date at which the error occurred.
Instructions
Reading
OK
NO
The contents of one record are shown below:
Error contents: If the Special I/O Unit error code is 0360 Hex, the Customiz-
able Counter Unit's error code is stored in bits 00 to 07.
Writing
Reading
OK
OK
Programming Device
Writing
Reading
OK
15
00 07
Special I/O Unit error code
Details 1
Details 2
Minutes
Seconds
Day
Hours
Year
Month
Section 6-2
Programming Device
Writing
OK
Writing
OK
00
91