Programming Devices
Mounting Dimensions
3-4
Programming Devices
Note
The dimensions when the Unit is mounted to the Rack and the cable connec-
tors are connected are shown below.
With soldered or crimped Fujitsu connector:
With pressure-welded Fujitsu connector;
Connecting cable: G79-@@@C-@@@-@@@
Development, transfer, and monitoring of ladder programs, editing and moni-
toring of I/O memory, and settings for the Unit Setup Area are carried out
using a Programming Device. Programming Devices include Hand-held Pro-
gramming Consoles and the CX-Programmer, which is installed onto a com-
puter. Connection to either is made using the peripheral port on the front of
the Unit.
1. The Programming Device cannot be used for the Unit if it is connected to
a serial communications port (peripheral port, RS-232C port) on the CPU
Unit.
2. When using the CX-Programmer, register the Customizable Counter Unit
as a CQM1H-CPU61.
Approx. 179
XW2Z-@@@
Section 3-4
53