Omron SYSMAC CS Series Operation Manual page 41

Customizable counter units
Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

Performance Specifications
Item
Exchange of
Continuous data exchange
general-pur-
between words in the SR Area in
pose data with
the Customizable Counter Unit
CPU Unit
and CIO Area allocated words in
the CPU Unit
Continuous data exchange
between user-set words in the
Customizable Counter Unit and
words allocated in the CPU Unit's
DM Area
Continuous data exchange
between LR Area words in the
Customizable Counter Unit and
user-set words in the CPU Unit
Methods for making Customizable Counter Unit's
initial settings
Mounting method
Setting switches
Display
Front panel
All models
connections
(CS1W-HIO01-V1/HCP22-V1/
HCA22-V1/HCA12-V1)
CS1W-HCP22-V1/HCA22-V1/
HCA12-V1 only
Super-capacitor backup data (in RAM)
Flash memory data
Super-capacitor backup time
Self-diagnosis function
4 input words and 4 output words (Inputs are to Customizable
Counter Unit)
I/O refresh is performed between words in the Customizable
Counter Unit's SR Area (SR 231 to SR 234 and SR 236 to SR 239)
and words allocated in the CPU Unit's CIO Area.
90 words max.
I/O refresh is performed for up to 90 words between user-set words
in the Customizable Counter Unit and words allocated in the CPU
Unit's DM Area.
Note Both inputs and outputs can be set in Customizable Counter
Unit's DM, AR, IR, LR, and EM Areas.
32 words max.
I/O refresh is performed for up to 32 words between the Customiz-
able Counter Unit's LR Area (in the order inputs ® outputs) and
user-set words in the CPU Unit.
Note Both inputs and outputs can be set in CPU Unit's CIO, WR,
AR, HR, DM, and EM Areas.
1.
Using the initial settings in the first 10 words (m to m+9) of the
words allocated in the CPU Unit's DM Area
2.
Using the Unit Setup Area (DM 6600 to DM 6655) of the Cus-
tomizable Counter Unit
Rack mounting
Rotary switches on front panel: Unit number (0 to 95)
Toggle switch: Programming Device connection switch (enables/dis-
ables servicing for the Programming Device connected to the
peripheral port)
25 LED indicators
The Unit is equipped with the following indicators: RUN (Unit opera-
tion), OPN (Unit program running), ERC (Unit error), ERH (CPU
Unit error), COMM (peripheral communications), In0 to In11 (for
inputs), and Out0 to Out7 (for outputs).
• One peripheral port (for Programming Device)
• One I/O connector (Compatible connector: FCN-361J024-AU
(socket) and FCN-360C024-J2 (connector cover) made by
Fujitsu)
In addition to the above, one special I/O connector (Compatible con-
nector: FCN-361J040-AU (socket) and FCN-360C040-J2 (connec-
tor cover) made by Fujitsu)
DM Area (DM 0000 to DM 6143), EM Area (EM 0000 to EM 2047)
(See note 1.), Error Log Area (DM 6144 to DM 6199), counter
present values
Note
1.
It is possible to set whether EM Area data is held or not
(with the default setting, data is cleared).
2.
If the power supply to the PLC is left OFF for longer
than the super-capacitor's backup (saving) time, the
above data will be lost. Therefore, before turning OFF
the CPU Unit's power supply for an extended period of
time, save the data using the ladder program. (Data
memory can be saved to flash memory.)
User program, general-purpose read-only portion of DM Area
(DM 6200 to DM 6599), Unit Setup Area (DM 6600 to DM 6655),
expansion instruction information (Also DM 0000 to DM 6143)
10 days at 25°C
CPU errors (WDT), memory errors, FALS system errors (FALS
instruction execution or maximum cycle time exceeded), FAL sys-
tem errors (FAL instruction execution, Unit Setup Area errors, etc.),
cycle time exceeded 10 ms, communications port errors, etc.
Section 2-1
Specification
21