Trunking System; Horn Alert Operation During Fleetsync Call; Configuring Horn Alert; Horn Alert Logic Signal - Kenwood TK-3180 Function Reference

Hide thumbs Also See for TK-3180:
Table of Contents

Advertisement

9 HORN ALERT
Table 9-2 Conditions for the Horn Alert to be activated in a
Conventional Group
Signaling Configuration
Audio
QT/DQT
control
Decode
configuration
configuration
None
None
QT/DQT or
Optional
Other than
signaling
none
Other than
none
None
None
QT/DQT and
Other than
Optional
none
signaling
Other than
none
9.2.2

Trunking System

In a Trunking system, you can configure the Horn Alert
function to each Group ID. Conditions to activate the
Horn Alert function are different between when the Horn
Alert function is configured to the Group ID and when the
Horn Alert function is not configured to the ID.
When the Horn Alert function is enabled, the HOR
terminal is activated when receiving an individual call.
This terminal operates according to the Horn Alert logic
signal configuration.
(Refer to 9.4.1 Horn Alert Logic Signal.)
The transceiver performs the pulse operation when
receiving the Fixed ID.
(Refer to 17.1.17 Fix ID.)
# When the PF Horn Alert Key is Configured:
The Horn Alert function is enabled when the PF Horn
Alert key is pressed when the Horn Alert function is
configured to a Group ID. The icon appears when the
Horn Alert function is enabled.
The Horn Alert function is not enabled even if the PF
Horn Alert key is pressed when the Horn Alert
function is not configured to a Group ID.
# When the PF Horn Alert Keys is not Configured:
The Horn Alert function is automatically enabled when
the Horn Alert function is configured to a Group ID.
The icon appears.
The Horn Alert function is not enabled when the Horn
Alert function is not configured to a Group ID.
Following are the conditions to activate the Horn Alert
function.
38
Conditions to
Activate the
Optional
Horn Alert
Signaling
Function
configuration
None
-
Other than
Carrier + Optional
none
signaling match
None
-
Other than
Carrier + Optional
None
signaling match
None
-
Other than
Carrier + Optional
none
signaling match
None
-
Carrier + QT/
Other than
DQT match +
none
Optional
signaling match
Function Reference
Table 9-3 Conditions to Activate the Horn Alert Function in
a Trunking System
Signaling Configuration
Horn Alert
Decode ID
configuration
Configuration
None
None
Disabled
Other than
None
Other than
None
None
None
Other than
Enabled
None
Other than
None
9.3
Horn Alert Operation During
FleetSync Call
The HOR terminal becomes active when receiving the
Status No. 89 in FleetSync. This function is activated
regardless of a Conventional Group and the Trunking
System configurations.
9.4

Configuring Horn Alert

You can configure the following items that are linked to
the Horn Alert function using KPG-89D.

Horn Alert Logic Signal

Off-hook Horn Alert
Horn Alert Mode
9.4.1
Horn Alert Logic Signal
This function allows you to configure the type of the HOR
terminal operation when the Horn Alert function is
activated.
You can configure the Horn Alert Logic Signal using KPG-
89D The following HOR terminal operation is available.
Conditions
to Activate
Optional
the Horn
Signaling
Alert
Configuration
Function
None
-
Other than
-
None
None
-
Other than
-
None
None
-
Other than
-
None
None
Decode ID
Decode ID +
Other than
Optional
None
Signaling
Match
Version: 1.11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-2180Tk-8180Tk-7180

Table of Contents