Data Transmit Modulation Delay Time; Random Access (Contention); Unit Id Serial Output; Selective Call Alert Led - Kenwood TK-3180 Function Reference

Hide thumbs Also See for TK-3180:
Table of Contents

Advertisement

22 FLEETSYNC
can reliably send the data even if the receiving party's
transceiver is performing Scan or using the Battery Saver
function.
You can configure the Transmit Delay Time using KPG-
89D. We recommend using the default configuration.
!
Configuration using KPG-89D
Configuring the Transmit Delay Time (Refer to
FPRG 6.12.3 Parameter tab - Transmit Delay
Time.)
22.9.15 Data Transmit Modulation
Delay Time
The Data Transmit Modulation Delay Time is the transmit
period of the unmodulated carrier prior to sending the
data in MSK modulation.
This delay time is used to stabilize the transceiver before
starting the MSK modulation. However, it may be difficult
to perform data communications when the transmit/
receive frequencies are completely different or the
transceiver is used in extremely cold areas. In such
cases, configure this delay time long in order to improve
data communications.
You can configure the Data Transmit Modulation Delay
Time using KPG-89D. We recommend using the default
configuration.
!
Configuration using KPG-89D
Configuring the Data Transmit Modulation Delay
Time (Refer to FPRG 6.12.3 Parameter tab - Data
Transmit Modulation Delay Time.)

22.9.16 Random Access (Contention)

This function allows the transceiver to randomize the
transmission start time for data when the channel
becomes free.
If multiple transceiver begin transmitting as soon as the
channel becomes free, transmission collision occur.
You can configure the Random Access function using
KPG-89D
Note: The Random Access period varies depending on the
configuration in the FleetSync > the General 1 tab >
FleetSync Baud Rate.
122
!
Configuration using KPG-89D
Configuring the Random Access function (Refer to
FPRG 6.12.3 Parameter tab - Random Access.)

22.9.17 Unit ID Serial Output

This function allows the transceiver to send the caller's
Fleet/ID from the transceiver's communication port when
the transceiver receives the PTT ID.
With this function enabled, the dispatcher can monitor the
transceivers.
You can enable/disable this function using KPG-89D.
Note: You must select "Data" in COM port when using the Unit ID
Serial Output function.
!
Configuration using KPG-89D
Configuring the Unit ID Serial Output (Refer to
FPRG 6.12.2 General 2 tab - Unit ID Serial
Output.)

22.9.18 Selective Call Alert LED

This function makes the SelCall Alert LED blink when
receiving a Selective Call.
Function.)
You can configure the SelCall Alert LED to blink using
KPG-89D.
!
Configuration using KPG-89D
Configuring the Selective Call Alert LED (Refer to
FPRG 6.12.1 General 1 tab - Selective Call Alert
LED.)

22.9.19 Message Display Type

This function allows you to configure the display when
receiving the Status/Short Message.
You can configure this function using KPG-89D. The
following main display types are available.
Function Reference
(Refer to 22.2 Selective Call
Version: 1.11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-2180Tk-8180Tk-7180

Table of Contents