Requirements
For use in the battery module or in the battery expansion module of the RTU, high current
resistant lithium metal batteries (primary cells, cannot be recharged) are required.
The batteries must meet the following requirements:
● Electrical data
– Nominal voltage (V
– Min permanent current:1800 mA
– Min. pulsed current:4000 mA
– Important:
● Geometric data
– Size acc. to ANSI: D (Mono)
– Maximum diameter: 33.4 mm
– Maximum height: 61.5 mm
Allowed battery types
Saft, LSH 20
Technical specifications - LSH 20
Brand and battery type
Vendor
Type
Battery type:
Electrical data
Voltage (nominal)
RTU3030C
Operating Instructions, 09/2017, C79000-G8976-C382-04
): 3.6 V
nom
Fuse against short-circuit (overheating protection): Fuse or temperature-dependent
resistor
Saft
LSH 20
D cell, lithium thionyl chloride (LiSOCl
3.6 V
)
2
Accessories