Setting IPSI duplication (high/critical
reliability only)
1
Type
change system-parameters duplication
change system-parameters duplication
Enable Operation of PNC Duplication? y
Enable Operation of IPSI Duplication? y
2
Set the
3
Press
Enter
Setting alarm activation level
1
Type
change system-parameters maintenance
change system-parameters maintenance
OPERATIONS SUPPORT PARAMETERS
CPE Alarm Activation Level: none
SCHEDULED MAINTENANCE
Update LSPs When Saving Translations: y
System Clocks/IPSI Interchange: no
2
In the
CPE Alarm Activation Level
depending on the level the customer wants and press
3
Repeat for each IPSI.
Installing the translation file
1
Type
reset system 4
2
Type
save translations
Saving translations
•
Type
save translations
Installing the Avaya S8500 Media Server with an Avaya G650 Media Gateway
December 2003
DUPLICATION RELATED SYSTEM PARAMETERS
Enable Operation of IPSI Duplication?
to effect the changes.
MAINTENANCE-RELATED SYSTEM PARAMETERS
Start Time: 22 : 00
Stop Time: 06 : 00
Save Translation: daily
Command Time-out (hours): 2
Control Channel Interchange: no
and press Enter to copy the translation files to the hard drive.
and press Enter to save the translations to the hard drive.
and press Enter to save the IPSI translations to the hard drive.
and press
Enter
field to
y
.
and press Enter.
field, select
(default),
none
to effect the changes.
Enter
Customizing the media server
Page
1 of
1
Page 1 of 3
,
, or
,
warning
minor
major
93