Figure 106: Typical wiring to a telephone
Figure notes
1
Power Supply Kit
2
2.5, 5.0, or 8.0 Amp Hour Battery
3
1146B2 Distribution Unit
4
1145B2 Power Supply
5
Circuits 1-16
6
Circuits 17-32
7
Port Circuit
8
Main Distribution Frame

Resetting LEDs on power distribution unit

A red LED next to any of the 32 power output connectors indicates a short circuit in the building wiring
or the terminal equipment. To reset the LED:
1
Disconnect the terminal equipment from the wall jack.
2
If the LED goes off, the terminal equipment is faulty and must be replaced. If the LED is still lit,
find and repair the short circuit in the building wiring.
3
Reconnect the terminal equipment to the wall jack and retest terminal equipment operation.
Installing the Avaya S8500 Media Server with an Avaya G650 Media Gateway
December 2003
1
2
11
4
12
7
9
Installing and wiring telephone power supplies
3
5
14 6
14
8
13
10
9
9
Modular Cord
10
Pins 7 and 8 (Display Terminal
Power)
11
AC Input
12
Installer-Provided Ground Wire
13
ISDN/ Display System Protocol
Terminal
14
Circuits 1-32