On the trunk identification label at the bottom of the panel, record the trunk line, extension, and
location for each circuit.
7
To each telephone designated as an emergency terminal, attach a label identifying it as such. The
labels are provided with the unit.
8
Check for normal operation as follows:
If all of the above conditions are not met, remove the panel from service and replace it with a new
panel.
9
Check for transfer operation as follows:
If all of the above conditions are not met, remove the panel from service and replace it with a new
panel.
.
Table 34: Trunk/test switches
Switch
number
1
2
3
4
5
6
7
8
9
10
11
12
Installing the Avaya S8500 Media Server with an Avaya G650 Media Gateway
December 2003
Place the test switch (switch 12) in NORMAL OPERATION.
Ensure the power supply is providing -48 VDC at 80 mA maximum. The power LED
should be ON.
Check wiring connections.
Verify there is dial tone on all emergency transfer sets.
Place the test switch (switch 12) in the ACTIVATED position.
The power LED should be OFF.
Verify there is dial tone on all emergency transfer sets.
Circuit
number
1
1
2
2
3
3
4
4
5
5
Not Used
Test Switch
Installing and wiring telephones and trunks