Checking Circuit Packs - Avaya S8500 Manual

Media server, media gateway
Hide thumbs Also See for S8500:
Table of Contents

Advertisement

Table 6: Comcodes for the G650 4 of 4
Comcode
Description
901007120
ITW LINX ground bar (used with above)
406304816
ITW LINX replacement fuse
103972758
Data link protector (1 circuit)
103972733
Data link protector (8 circuits)
407063478
Electrostatic discharge (ESD) wrist strap
105197792
Retainer, 4B
* The G650 can use either AC or DC power. The G650 must have either a DC power cable (700252638) or one of the
country-specific AC power cables listed in this table. For installations that do not use one of the country-specific power
cables listed in this table, procure a local power cord.
† The G650 must always operate with all slots blocked with circuit packs and apparatus blanks to ensure that it meets its
thermal and EMI/EMC environmental performance criteria. (It must also always operate with the door closed.)
‡ This apparatus blank is required for installations that use oversized circuit packs such as the TN755B or the TN2202. This
ensures that all slots are blocked.

Checking circuit packs

Be sure all circuit packs are fully inserted into the proper slots according to the Customer Service
Document (CSD). See
Report any discrepancies in circuit pack type or quantity to your Avaya representative.
Table 7: G650 Media Gateway circuit pack placement
Circuit pack information
Circuit pack name
655A power supply
Redundant 655A power
supply
TN2312BP IPSI
Second TN2312BP IPSI
TN799DP (or greater
suffix) CLAN
TN2302 media processor
TN771 maintenance/test
board
Port circuit packs
Trunk circuit packs
Installing the Avaya S8500 Media Server with an Avaya G650 Media Gateway
December 2003
Table 7, G650 Media Gateway circuit pack placement,
Required or optional
Required
Optional
Required
Optional
Optional
Optional
One per customer
location
Included
in basic
cabinet
No
No
No
No
No
Yes
Placement information
Slot number
Required or recommended
0
Required
15
If it is present, it must be in slot 15.
A01
Required
B01
If it is present, it must be in slot B01.
2
Recommended
14
Recommended
Any slot
Slots on the
Recommended
left
Slots on the
Recommended
right
FRU
Optional
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
on page 103.
103

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G650

Table of Contents