Connecting the main distribution frame to stations and the public switched telephone network

4-pair station circuits

Four-pair circuits, via station cables, can be run directly from an equipment room MDF to a 258A or
BR2580A adapter as shown in
pair station cables connect the adapter to the information outlets.
The 4-pair station cables can be run directly from the equipment room to the information outlets if 4-pair
terminal blocks are used in the distribution field. See
location,
on page 196. The station cables must be field-terminated on the 110-type terminal blocks.
If 110-type terminal blocks are used with a modular plug-ended station cable, an adapter can be
connected directly to the 110-type terminal block connectors. See
room or satellite location,

3-pair to 4-pair station circuit distribution

Figure 73, 3-pair to 4-pair satellite location connectivity,
from an equipment room MDF to a satellite location using 110-type hardware. Four-pair circuits are
distributed from the satellite location to the information outlets.
Three-pair circuits can also be run directly from the equipment room MDF to a 356A adapter as shown in
Figure 74, 3-pair to 4-pair circuit distribution and connectivity,
connect the adapter to the information outlets. Four-pair station cables can be run directly from a satellite
location to the information outlets as previously described.
Installing the Avaya S8500 Media Server with an Avaya G650 Media Gateway
December 2003
Figure 70, 4-pair circuit distribution and connectivity,
on page 197.
NOTE:
Bridged taps are not allowed on any part of the station wiring.
Figure 71, 4-pair run to equipment room or satellite
Figure 72, 4-pair run to equipment
on page 198 shows the 3-pair circuit distribution
on page 199. Four-pair station cables
on page 196. The 4-