Installing sneak fuse panels

For general information, see
Figure 78, Model 507B sneak fuse panel,
protection. The panel contains two 25-pair connectors, fuse removal tool, and fifty 220029 sneak fuses
(and two spares). See
1
Locate the 507B near the network interface or the main distribution frame (MDF).
2
Hold the panel against the mounting surface and mark the mounting screw locations. Drill pilot
holes at the marked locations and partially install a locally obtained #12 x 3/4-inch screw into the
two bottom mounting slots.
3
Slide the sneak fuse panel onto the mounting screws and tighten the screws securely.
4
Install a locally obtained #12 x 3/4-inch screw into the top two mounting slots and tighten
securely.
5
Repeat the procedure for each sneak fuse panel.
6
Secure the B25A cable to the panel with the captive screw on the connector and a supplied cable
tie.
Installing the Avaya S8500 Media Server with an Avaya G650 Media Gateway
December 2003
Installing sneak current and off premise protection
on page 205, or equivalent, is recommended for sneak current
Table 18, Sneak fuse connector pinout,
on page 204.
on page 206 for pinout data.