Installing and wiring telephones and trunks

Adjunct power connection locations

Figure 95, Example adjunct power connections,
adjunct power. Adjunct power for station equipment may be supplied from the equipment room, satellite
location, or the work location.
For this figure, the following example is used:
1
If 25 telephones are connected to the media gateway and all 25 telephones need adjunct power,
install a bulk power supply in the equipment room.
2
If only ten of the telephones need adjunct power, install a bulk power supply at the satellite
location.
3
If only one telephone needs adjunct power, install the individual power supply at the work
location.
Figure 95: Example adjunct power connections
Figure notes
1
Typical Display Telephone
2
Individual Power Supply (Such as
1151B1 or 1151B2)
3
Information Outlet (Modular Jack)
4
4-Pair D-Inside Wire (DIW) Cable
5
Satellite Site or Adapter Location
6
25-Pair D-Inside Wire (DIW) Cable
7
Station Side of Main Distribution Frame
(MDF)
246
13
1
3
2
Installing the Avaya S8500 Media Server with an Avaya G650 Media Gateway
on page 246 shows typical connection locations for
12
5
7
4
6
14
14
8
100P6A Patch Cord or Jumpers
9
Media Gateway Side of Main
Distribution Frame (MDF)
10
25-Pair Cable to Media Gateway
(Analog Line Circuit Pack)
11
Equipment Room
12
Satellite Location
13
Work Location
14
Bulk Power Supply (such as 1145B)
11
9
8
10
cydfadjn KLC 020599
December 2003

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G650

Table of Contents