1152A1 Mid-Span Power Distribution Unit - Avaya G700 Installation And Upgrades

Media gateway controlled by media server
Hide thumbs Also See for G700:
Table of Contents

Advertisement

7 Connecting Telephones and Adjunct Systems: Installation and Wiring Telephones and Power Supplies
Local and Phantom Power
An attendant console's maximum distance from the system is limited.
See
Table
2.
Table 2. Attendant Console Cabling Distances
Enhanced Attendant
Console (302D)
With Selector Console
Phantom powered
Locally powered
Without Selector Console
Phantom powered
Locally powered

1152A1 Mid-Span Power Distribution Unit

The 1152A1 Mid-Span Power Distribution Unit (PDU) is an Ethernet power supply that provides power to
up to 24 46xx-series IP telephones or wireless LAN (WLAN) access points. This unit is used with a
10/100BaseTx standard Ethernet network over a standard TIA/EIA-568 Category 5, 6 or 6e cabling plant.
The 1152A1 meets the current requirements of the IEEE802.3af standard for resistive detection.
The 1152A1 PDU complies with the Underwriters Laboratories Inc. (UL) standard UL 1950, second
edition.
Table 3. 1152A1 PDU UL 1950 Compliance
Complies
Approved
CSA C22.2 No.950 Std.
Approved
CE Regulatory Compliance
Approved
EN 60950
Approved
TUV EN 60950
For safety instructions, see
"Connect the Cables" on page
258
24 AWG Wire (0.26 mm
Feet
Meters
800
244
5000
1524
1400
427
5000
1524
UL 1950
"Important Safety Instructions" on page
260.
Installation and Upgrades for G700 with S8300 or S8700
2
)
26 AWG Wire (0.14 mm
Feet
Meters
500
152
3400
1037
900
274
3400
1037
259. For installation instructions, see