7-1
Overview of Motor Control Methods
Select an appropriate motor control mode for the motor to be driven and the control method.
When you drive an induction motor (IM), set [AA121]=00 to 10.
Set [AA121] = 11 or 12 to drive a synchronous motor (SM)/permanent magnet motor (PMM).
The characteristics of the control operation may be improved by automatic tuning.
Whether the currently-selected mode is the control mode for induction motors or that for synchronous
motors (SMs)/permanent magnet motors (PMMs) can be checked by [dC-45] IM/SM(PMM) monitor.
Precautions for Correct Use
• As improper settings for a given motor result in performance below its potential characteris-
tics, be sure to set up appropriately.
• See 6-2 Parameter Setting for Motor Related on page 6-8 for checking.
• To drive multiple induction motors (IMs) by a single inverter, it is recommendable to use it
with V/f control's constant torque characteristics.
• An exemplar selection of control mode will be shown in the following section. Some of your
systems may have more suitable modes than what is selected as the example.
Parameter
Item
Control mode
selection,
1st-motor
IM/SM monitor
*1. Cannot be selected if [Ub-03] duty spec selection is 01 (LD) or 00 (VLD).
*2. Cannot be selected if [Ub-03] duty spec selection is 00 (VLD).
Note IM: Induction motor
SM (PMM): Synchronous motor (permanent magnet motor)
High-function General-purpose Inverter RX2 Series User's Manual
Parameter
Data
00
01
02
03
04
05
06
[AA121]
07
08
09
10
11
12
00
[dC-45]
01
Description
V/f control-constant torque characteristics (IM)
V/f control-reducing torque characteristics (IM)
V/f control-free V/f (IM)
Automatic torque boost (IM)
V/f control-constant torque characteristics (IM)
with sensor
V/f control-reducing torque characteristics (IM)
with sensor
V/f control with sensor-free V/f (IM)
Automatic torque boost (IM) with sensor
Sensorless vector control (IM)
Zero-Hz range sensorless vector control (IM)
Vector control (IM) with sensor
Synchronous-start type sensorless vector con-
trol (SM/PMM)
IVMS-start type sensorless vector control
*2
(SM/PMM)
Induction motor IM being selected.
Synchronous motor SM (permanent magnet
motor PMM) being selected.
7 Advanced Settings
Default
data
00
*1
*1
-
7 - 3