2 Design
 Power Input/Output
(Wiring example)
Control circuit terminal area
DC24V external
External
24V terminal
P24
DC24V external power supply
When 24 V power is supplied to P+ and P- from an external source, change of parameters and commu-
nication of optional devices are enabled even without main power supply.
Terminal
symbol
P24
P+
P-
2 - 30
power supply
P+
P-
Terminal
name
24V output
24 VDC power supply for contact signal
power
The common terminal is P-.
terminal
External
24V input
Input an external 24 VDC power to the
terminal
inverter. With input of 24 V power, you
(24V)
can change parameter settings or oper-
ate optional communication without using
Terminal
a control power supply
for P24/P+
(0 (zero) V)
Description
100mA output at maximum
Allowable input voltage
Maximum power consumption 1A
High-function General-purpose Inverter RX2 Series User's Manual
Electrical characteristics
24 VDC±10%