3 Operation
Example1) Change [Hb103] First IM motor pole number
Set-up procedure
Hb103
00
2P
01
4P
02
6P
03
8P
H: Motor control
Hb102
First IM motor capacity . .
Example2) Change [Hb104] First IM motor base frequency.
Set-up procedure
Output Frequency
Hb104
First IM motor base frequency
H: Motor control
Hb102
First IM motor capacity . .
In the scroll mode screen (L02), (1) you can jump to the parameter at the top of each group by using the
right and left (
the group by using F2 (Next group) key.
(1) You can jump to the top parameter of each group by using the right and left (
(...<->All parameters<->d: monitor<->F: Command monitor/setting<->...<->U: Initial setting, PDN <->All
parameters<->...)
3 - 16
Action
If the number of motor poles is 2, using the up and down
(
F2(Save) key.
Data is saved when the F2(2) key is pressed. It is still saved
even after the device is turned off. When configuring an item,
the entire screen changes to the screen for setting the item.
When not saving the setting after changing it, press the
F1(Back) key. The screen returns to the parameter list dis-
play.
To confirm if the data is correctly changed, check the lower
section of the parameter display. Press the F1(1) key three
times to return to the monitor.
5.50kW
0:2P
60.00Hz
Action
You can change the right-most digit of data area. Change the
value using the arrow (
then press the F2(2) key. To 3.9.
0.00 Hz
(Tips)
In the figure on the left, base frequency is changed to
50.00Hz. Data is saved when the F2(2) key is pressed. It is
50.00 Hz
still saved even after the device is turned off. You can make
[0.00-60.00]
adjustments while performing monitoring. The monitor on the
upper area shows the parameter selected in the monitor of
the capital letters.
To confirm if the data is correctly changed, check the lower
section of the parameter display. Press the F1(1) key three
times to return to the monitor.
5.50kW
1:4P
50.00Hz
) keys or (2) jump to the parameter at the top of the sub-group (AA, Ab etc.) of
High-function General-purpose Inverter RX2 Series User's Manual
) keys, adjust it to "00 2P", and then press the
) keys, and
) keys.