Omron RX2 Series User Manual page 124

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

2 Design
 Pullout Method
1
Push the gray colored part on the PG Option Unit terminal block with a flathead screwdriver (2.5
mm widths or narrower), and the aperture for wire-inserting will open.
2
While you are holding the screwdriver in the hole, pull out the wire or pin-terminal.
3
Pull out the screwdriver.
Push the gray colored
part with your flathead
screwdriver.
 Method of Disconnecting the Connector
1
Pull down the lock lever to the direction indicated by the arrow to release the lock.
2
Pull out the connector.
PG Option Unit Disconnection Detection
The encoder input terminal ((EAP/EAN/EBP/EBN/EZP/EZN) has a function to detect disconnection
when the wires are not connected. When you do not connect any encoders
(EAP/EAN/EBP/EBN/EZP/EZN not connected), turn the DIP switch 1 and 2 to OFF in order to disable
the disconnection function.
As for the encoder without Z-phase, turn the DIP switch 2 to OFF to disable the detection of Z-phase
disconnection.
2 - 70
Pull out the wire.
Pull out the screw driver.
Pull down the
lock lever.
Pull out the
connector.
High-function General-purpose Inverter RX2 Series User's Manual