Deceleration-stop at power fail-
bA-30
-
ure
Decel-stop at power failure
bA-31
starting voltage
Decel-stop at power failure con-
bA-32
trol target level
Decel-stop at power failure
bA-34
deceleration time
Decel-stop at power failure freq.
bA-36
width at deceleration start
Decel-stop at power failure
bA-37
DC-bus voltage constant control
P-gain
Decel-stop at power failure
bA-38
DC-bus voltage constant control
I-gain
Over-voltage suppression
bA140
enable, 1st-motor
Over-voltage suppression active
bA141
level, 1st-motor
Over-voltage suppression
bA142
action time, 1st-motor
DC bus constant control propor-
bA144
tional gain, 1st-motor
DC bus constant control integral
bA145
gain, 1st-motor
Over magnetization decelera-
bA146
tion function selection, 1st_mo-
tor
Over magnetization output filter
bA147
time constant, 1st_motor
Over magnetization voltage
bA148
gain, 1st_motor
Over magnetization level set-
bA149
ting, 1st_motor
bA-60
Dynamic brake usage rate
bA-61
-
Dynamic brake selection
bA-62
-
Dynamic brake active level
bA-63
-
Dynamic brake resister value
Cooling FAN control method
bA-70
selection
Cooling FAN accumulation run-
bA-71
-
ning time clear selection
High-function General-purpose Inverter RX2 Series User's Manual
Name
00 (Disabled)/
01 (Enabled: deceleration stop)/
02 (Enabled: no recovery)/
03 (Enabled: with recovery)
(200 V class) 0.0 to 410.0 (V)
(400 V class) 0.0 to 820.0 (V)
(200 V class) 0.0 to 410.0 (V)
(400 V class) 0.0 to 820.0 (V)
0.01 to 3600.00 (s)
0.00 to 10.00 (Hz)
0.00 to 5.00
0.00 to 150.00 (s)
00 (Disabled)/
01 (DC voltage constant deceleration)
02 (Acceleration only at deceleration)/
03 (Acceleration at constant speed/deceleration)
(200 V class) 330.0 to 400.0 (V)
(400 V class) 660.0 to 800.0 (V)
0.00 to 3600.00 (s)
0.00 to 5.00
0.00 to 150.00 (s)
00 (Disabled)/01 (Regular operation)/
02 (Operation only at deceleration)/
03 (Level mode)/
04 (Level mode only at deceleration)
0.00 to 1.00(s)
50 to 400 (%)
(200 V class) 330.0 to 400.0 (V)
(400 V class) 660.0 to 800.0 (V)
0.0 to 10.0 ×
([bA-63]/minimum resistance)
00 (Disabled)/
01 (Enabled: disabled at stop)/
02 (Enabled: enabled at stop)
(200 V class) 330.0 to 400.0 (V)
(400 V class) 660.0 to 800.0 (V)
Minimum resistance to 600 (Ω)
00 (Always ON)/
01 (ON during operation)/
02 (Temperature dependent)
00 (Disabled)/01 (Clear)
Appendices C Table of Parameters
Data range
2
*4
(%)
*4
Initial value
Note
00
(200 V class) 220.0
(400 V class) 440.0
(200 V class) 360.0
(400 V class) 720.0
1.00
0.00
0.20
1.00
00
(200 V class) 380.0
(400 V class) 760.0
1.00
0.20
1.00
02
0.30
100
(200 V class) 360.0
(400 V class) 720.0
10.0
00
(200 V class) 360.0
(400 V class) 720.0
Minimum resis-
*4
tance
00
00
C - 35
C