Omron RX2 Series User Manual page 902

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

Appendices C Table of Parameters
Codes that
can be
Code
changed
during
operation
Low current signal output mode
CE101
selection, 1st motor
Low current detection level 1,
CE102
1st motor
Low current detection level 2,
CE103
1st motor
Over current signal output mode
CE105
selection, 1st motor
Over current detection level 1,
CE106
1st motor
Over current detection level 2,
CE107
1st motor
Arrival frequency setting during
CE-10
acceleration 1
Arrival frequency setting during
CE-11
deceleration 1
Arrival frequency setting during
CE-12
acceleration 2
Arrival frequency setting during
CE-13
deceleration 2
Over torque level (Forward driv-
CE120
ing), 1st motor
Over torque level (Reverse
CE121
regenerative), 1st motor
Over torque level (Reverse driv-
CE122
ing), 1st motor
Over torque level (Forward
CE123
regenerative), 1st motor
Electronic thermal warning level
CE-30
(MTR)
Electronic thermal warning level
CE-31
(CTL)
CE-33
Zero speed detection level
Cooling FAN over-heat warning
CE-34
level
Accum.RUN(RNT)/Accum.Pow
CE-36
er-on (ONT) time setting
Window comparator for [Ai1]
CE-40
higher level
Window comparator for [Ai1]
CE-41
lower level
Window comparator for [Ai1]
CE-42
hysteresis width
Window comparator for [Ai2]
CE-43
higher level
Window comparator for [Ai2]
CE-44
lower level
Window comparator for [Ai2]
CE-45
hysteresis width
Window comparator for [Ai3]
CE-46
higher level
Window comparator for [Ai3]
CE-47
lower level
C - 54
Name
00 (During acceleration/deceleration, at constant
speed)/
01 (Only at constant speed)
(0.0 to 2.0)
× Inverter rated current
(0.0 to 2.0)
× Inverter rated current
00 (During acceleration/deceleration, at constant
speed)/
01 (Only at constant speed)
(0.0 to 2.0)
× Inverter rated current
(0.0 to 2.0)
× Inverter rated current
0.00 to 590.00 (Hz)
0.00 to 590.00 (Hz)
0.00 to 590.00 (Hz)
0.00 to 590.00 (Hz)
0.0 to 500.0 (%)
0.0 to 500.0 (%)
0.0 to 500.0 (%)
0.0 to 500.0 (%)
0.00 to 100.00 (%)
0.00 to 100.00 (%)
0.00 to 100.00 (%)
0 to 200 (°C)
0 to 100000 (hr)
0 to 100 (%)
0 to 100 (%)
0 to 10 (%)
0 to 100 (%)
0 to 100 (%)
0 to 10 (%)
-100 to 100 (%)
-100 to 100 (%)
High-function General-purpose Inverter RX2 Series User's Manual
Data range
*1
*1
*1
*1
Initial value
Note
01
1.0
× Inverter rated
current
1.0
× Inverter rated
current
01
1.0
× Inverter rated
current
1.0
× Inverter rated
current
0.00
0.00
0.00
0.00
100.0
100.0
100.0
100.0
80.00
80.00
0.50
120
0
100
0
0
100
0
0
100
-100

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents