Exemplar Operation
3rd speed [Ab-13], 4th speed [Ab-14]
Output
frequency
Acceleration or
deceleration
time
Multiple
speeds
FW
Example (1) If the multi-speed 3rd speed is engaged and the revolution is accelerating, the enabled
acceleration time is the acceleration time setting for Multispeed-3 [AC-38].
Example (2) If the multi-speed 1st speed is engaged and the revolution is decelerating, the enabled
deceleration time is the deceleration time setting for Multispeed-3 [AC-40] for the multi-speed 3rd
speed that has been engaged until the multi-speed 1st speed is engaged.
High-function General-purpose Inverter RX2 Series User's Manual
If the set frequency is the same, only the acceleration or
deceleration time can be changed.
2nd speed [Ab-12]
1st speed [Ab-11]
Example (1)
1st speed
2nd speed
3rd speed
acceleration
acceleration
acceleration
[AC-30] [AC-34] [AC-38] [AC-40] [AC-42]
1st speed
2nd speed 3rd speed
6 Basic Parameter Settings
3rd speed
4th speed
Command
deceleration
acceleration
unchanged
2nd speed 4th speed
3rd speed
Example (2)
3rd speed
4th speed
4th speed
deceleration
acceleration
deceleration
[AC-40] [AC-42] [AC-44]
4th speed
1st speed