Parameter Mode (Code o)
Codes that
can be
Code
changed
during
operation
Operation mode on option card error
oA-10
(SLOT-1)
oA-11
Communication Watch Dog Timer
oA-12
-
Action selection at communication error
Run command enable option during the
oA-13
-
option card (SLOT-1) start-up
Operation mode on option card error
oA-20
(SLOT-2)
oA-21
Communication Watch Dog Timer
oA-22
-
Action selection at communication error
Run command enable option during the
oA-23
-
option card (SLOT-2) start-up
Operation mode on option card error
oA-30
(SLOT-3)
oA-31
Communication Watch Dog Timer
oA-32
-
Action selection at communication error
Run command enable option during the
oA-33
-
option card (SLOT-3) start-up
Codes that
can be
Code
changed
during
operation
ob-01
-
Encoder constant setting
ob-02
-
Encoder position selection
ob-03
-
Motor gear ratio numerator
ob-04
-
Motor gear ratio denominator
ob-10
-
Pulse train detection object selection
ob-11
-
Mode selection of pulse train input
ob-12
Pulse train frequency Scale
Pulse train frequency Filter time con-
ob-13
stant
ob-14
Pulse train frequency Bias value
ob-15
Pulse train frequency High Limit
Pulse train frequency detection low
ob-16
level
High-function General-purpose Inverter RX2 Series User's Manual
Name
00 (Error)/01 (Continue operation)
0.00 to 100.00 (s)
00 (Error)/
01 (Trip after deceleration stop)/02 (Ignore)/
03 (Free run)/04 (Deceleration stop)
00 (Operation command disabled)/
01 (Operation command enabled)
00 (Error)/01 (Continue operation)
0.00 to 100.00 (s)
00 (Error)/
01 (Trip after deceleration stop)/02 (Ignore)/
03 (Free run)/04 (Deceleration stop)
00 (Operation command disabled)/
01 (Operation command enabled)
00 (Error)/01 (Continue operation)
0.00 to 100.00 (s)
00 (Error)/
01 (Trip after deceleration stop)/02 (Ignore)/
03 (Free run)/04 (Deceleration stop)
00 (Operation command disabled)/
01 (Operation command enabled)
Name
32 to 65535 (pls)
00 (Phase-A is leading)/
01 (Phase-B is leading)
1 to 10000
1 to 10000
00 (Command)/
01 (Pulse string position command)
00 (90° phase difference)/
01 (forward/reverse rotation command and rotation
direction)/
02 (forward/reverse rotation pulse string)
0.05 to 200.0 (kHz)
0.01 to 2.00 (s)
-100.0 to 100.0 (%)
0.0 to 100.0 (%)
0.0 to 100.0 (%)
Appendices C Table of Parameters
Data range
Data range
Initial
Note
value
00
1.00
01
00
00
1.00
01
00
00
1.00
01
00
C
Initial
Note
value
1024
00
1
1
00
01
25.00
0.10
0.0
100.0
0.0
C - 63