2 Design
 Input Terminals
• All COM terminals are at the same potential.
• When connecting a power supply between 1-9, A, B and COM, switch SW5 to the external power
supply (EX).
• You can switch between the sink/source logic of input terminals by SW6.
(Wiring example)
B
[USP]
[EXT]
• [ ] indicates the factory default setting.
Terminal
symbol
9, 8, 7,
6, 5, 4,
3, 2, 1
A
B
COM
2 - 24
A
9
8
COM
[FW]
[RV]
[CF2]
Terminal
name
You can select terminal functions
using the parameter settings corre-
Input
sponding to each terminal. You can
terminal
switch between the sink logic and
source logic by switching SINK/SRC
of SW6.
Pulse
When [CA-90] is set to 00, A, and B
input-A
terminals can be used as input termi-
nals.
You can select terminal functions
using the parameter settings corre-
sponding to each terminal.
Pulse
input-B
When [CA-90] is not set to 00, they
are used as terminals for pulse string
input.
The maximum input pulse is 32kpps.
Common
Common terminals for digital input
for input
terminals (1,2,3,4,5,6,7,8,9,A,B).
terminal
There are three COM terminals.
SW5
Input
7
6
5
COM
[CF1]
[2CH]
[FRS]
Description
High-function General-purpose Inverter RX2 Series User's Manual
Control circuit terminal
area
4
3
1
2
COM
[JG]
[RS]
[SCHG]
Electrical characteristics
Voltage between each input/COM
• ON voltage Min. DC18V
• OFF voltage Max. DC3V
• Maximum allowable voltage
DC27V
• Load current 5.6mA (at DC27V)
Voltage between each input/COM
• ON voltage Min. DC18V
• OFF voltage Max. DC3V
• Maximum allowable voltage
DC27V
• Load current 5.6mA (at DC27V)
• Maximum 32kpps pulse input
SW6