Modbus
Register
register
No.
spec. No.
Carrier speed setting,
332Dh
332Ch
1st-motor
Sprinkle carrier pattern
332Eh
332Dh
selection, 1st-motor
Automatic-carrier reduction
332Fh
332Eh
selection, 1st-motor
Automatic error reset
3336h
3335h
selection
Alarm signal selection at
3337h
3336h
Automatic error reset is active
Automatic error reset wait
3338h
3337h
time
3339h
3338h
Automatic error reset number
The number of retries after
3340h
3339h
instantaneous power failure
The number of retries after
3341h
3340h
under voltage
The number of retries after
3342h
3341h
over current
The number of retries after
3343h
3342h
over voltage
Selection of restart mode
3344h
3343h
@Instantaneous power fail-
ure/ under-voltage trip
Allowable under-voltage
3345h
3344h
power failure time
Retry wait time before motor
3346h
3345h
restart
Instantaneous power fail-
3347h
3346h
ure/under-voltage trip alarm
enable
Selection of restart mode
3348h
3347h
@over-current
Wait time of restart
3349h
3348h
@over-current
High-function General-purpose Inverter RX2 Series User's Manual
Parame-
Function name
ter No.
bb101
bb102
bb103
bb-10
bb-11
bb-12
bb-13
bb-20
bb-21
bb-22
bb-23
bb-24
bb-25
bb-26
bb-27
bb-28
bb-29
9 Communications Functions
R/W
Monitor or setting data
[Ub-03]=02: ND
0.5 to 16.0 (kHz)
[Ub-03]=01: LD
0.5 to 12.0 (kHz)
R/W
[Ub-03]=00: VLD
0.5 to 10.0 (kHz)
*3
00: Disabled
01: Pattern 1 enabled
R/W
02: Pattern 2 enabled
03: Pattern 3 enabled
00: Disabled
R/W
01: Enabled: current
02: Enabled: temperature
00: Disabled
01: Enabled with operation com-
R/W
mand OFF
02: Enable after the setting time
00: Output
R/W
01: Not output
R/W
0 to 600
R/W
0 to 10
R/W
0 to 16 / 255
R/W
0 to 16 / 255
R/W
0 to 5
R/W
0 to 5
00: 0Hz
01: (Frequency matching
02: Frequency entrainment
R/W
03: Detection speed
04: Trip after frequency matching
deceleration stop
R/W
3 to 250
R/W
3 to 1000
00: Disabled
01: Enabled at stop
R/W
02: Disabled at stop and deceler-
ation stop
00: 0Hz
01: Frequency matching
02: Frequency entrainment
R/W
03: Detection speed
04: Trip after frequency matching
deceleration stop
R/W
3 to 1000
Resolution
0.1kHz
-
-
-
-
1(s)
1
1
1
1
1
-
9
0.1(s)
0.1(s)
-
-
0.1(s)
9 - 67