13 Maintenance and Inspection

13-5-6 Life Alarming Output

When the life a component (smoothing capacitor or cooling fan on the board, excluding the main circuit
smoothing capacitor) is near its end, an alarm can be generated based on self-diagnosis. Use this
alarm as a sign of part replacement period. For details, see the life diagnosis monitor [dC-16] and out-
put terminal function selection [CC-01] to [CC-07]. Note that alarms are generated based on diagnosis
of designed expected life (not a guaranteed value). There will be differences due to use environments,
operating conditions, etc. Please conduct maintenance in advance.