Omron RX2 Series User Manual page 399

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

 Parameter
Item
DC braking
selection,
1st-motor
Braking type
selection,
1st-motor
DC braking fre-
quency, 1st-motor
DC braking delay
time, 1st-motor
DC braking active
time at stop,
1st-motor
DC braking opera-
tion method
selection,
1st-motor
Input terminal func-
tion
Control mode
selection,
1st-motor
High-function General-purpose Inverter RX2 Series User's Manual
Parameter
Data
00
01
[AF101]
02
01
[AF102]
02
0.00 to
[AF103]
590.00(Hz)
[AF104]
0.00 to 5.00(s)
[AF106]
0.00 to 60.00(s)
00
[AF107]
01
[CA-01] to
054
[CA-11]
08
[AA121]
09
10
Description
Internal DC braking: Disabled
Internal DC braking: Enabled
Internal DC braking: Enabled (The braking oper-
ates only with the set braking frequency.)
Enables the speed servo-lock.
Enables the position servo-lock.
With internal DC braking enabled, DC braking is
started when the output frequency reaches or
becomes less than the frequency set for stop-
ping.
Specifies the delay in starting DC braking while
temporally shutting off the output.
Sets the duration for DC braking. This setting is
valid for the [DB] terminal in edge mode or for
the internal DC braking. When "0.00 second" is
specified, no braking operation will be per-
formed.
Edge mode (Examples 1-a to 6-a )
Level mode (Examples 1-b to 6-b )
Controls with the servo-on mode using the
[SON] terminal.
OFF: Servo lock is disabled.
ON: Servo lock is enabled.
Sensorless vector control
Zero-speed range sensorless vector control
Vector control with sensor
7 Advanced Settings
Default
data
00
00
0.50
000
0.00
01
-
00
7 - 91
7