Appendices C Table of Parameters
Codes that
can be
Code
changed
during
operation
Cb-01
○
Filter time constant of Terminal [Ai1]
Cb-03
○
Start value of Terminal [Ai1]
Cb-04
○
End value of Terminal [Ai1]
Cb-05
○
Start rate of Terminal [Ai1]
Cb-06
○
End rate of Terminal [Ai1]
Cb-07
○
Start point selection of Terminal [Ai1]
Cb-11
○
Filter time constant of Terminal [Ai2]
Cb-13
○
Start value of Terminal [Ai2]
Cb-14
○
End value of Terminal [Ai2]
Cb-15
○
Start rate of Terminal [Ai2]
Cb-16
○
End rate of Terminal [Ai2]
Cb-17
○
Start point selection of Terminal [Ai2]
Cb-21
○
Filter time constant of Terminal [Ai3]
Cb-22
-
Terminal [Ai3] selection
Cb-23
○
Start value of Terminal [Ai3]
Cb-24
○
End value of Terminal [Ai3]
Cb-25
○
Start rate of Terminal [Ai3]
Cb-26
○
End rate of Terminal [Ai3]
[Ai1] Voltage/Current zero-gain
Cb-30
-
adjustment
Cb-31
-
[Ai1] Voltage/Current gain adjustment
[Ai2] Voltage/Current zero-gain
Cb-32
-
adjustment
Cb-33
-
[Ai2] Voltage/Current gain adjustment
[Ai3] Voltage/Current zero-gain
Cb-34
-
adjustment
Cb-35
-
[Ai3] Voltage gain adjustment
Cb-40
○
Thermistor selection
Cb-41
-
Thermistor gain adjustment
Cb-51 to
-
Reserved
Cb-57
C - 46
Name
1 to 500 (ms)
0.00 to 100.00 (%)
0.00 to 100.00 (%)
0.0 to [Cb-06] (%)
[Cb-05] to 100.0 (%)
00 (Start amount)/01 (0%)
1 to 500 (ms)
0.00 to 100.00 (%)
0.00 to 100.00 (%)
0.0 to [Cb-16] (%)
[Cb-15] to 100.0 (%)
00 (Start amount)/01 (0%)
1 to 500 (ms)
00 (Single)/
01 (Added to Ai1/Ai2: with reversibility)/
02 (Added to Ai1/Ai2: without reversibility)
-100.00 to 100.00 (%)
-100.00 to 100.00 (%)
-100.0 to [Cb-26]
[Cb-25] to 100.0
-100.00 to 100.00
0 to 200.00
-100.00 to 100.00
0 to 200.00
-100.00 to 100.00
0 to 200.00
00 (Disabled)/
01 (PTC resistance value enabled)/
02 (NTC resistance value enabled)
0.0 to 1000.0
-
High-function General-purpose Inverter RX2 Series User's Manual
Data range
Initial
Note
value
16
0.00
100.00
0.0
100.0
01
16
0.00
100.00
20.0
100.0
01
16
00
-100.00
100.00
-100.0
100.0
0.00
100.00
0.00
100.00
0.00
100.00
00
100.0