Modbus
Register
register
No.
spec. No.
Logical calculation target 2
37B0h
37AFh
selection of LOG6
Logical calculation symbol
37B1h
37B0h
selection of LOG6
Logical calculation target 1
37B2h
37B1h
selection of LOG7
Logical calculation target 2
37B3h
37B2h
selection of LOG7
Logical calculation symbol
37B4h
37B3h
selection of LOG7
[FM] monitor output wave
37DDh
37DCh
form selection
[FM] monitor output base fre-
37Deh
37DDh
quency (at PWM output)
37DFh
37DEh
[FM] monitor output selection
37E0h
37DFh
[Ao1] monitor output selection Cd-04
37E1h
37E0h
[Ao2] monitor output selection Cd-05
Analog monitor adjust mode
37E6h
37E5h
enable
Filter time constant of
37E7h
37E6h
[FM]monitor
37E8h
37E7h
[FM] Data type selection
37E9h
37E8h
[FM] monitor bias adjustment
37Eah
37E9h
[FM] monitor gain adjustment
Output level setting at [FM]
37Ebh
37EAh
monitor adjust mode
Filter time constant of [Ao1]
37F1h
37F0h
monitor
37F2h
37F1h
[Ao1] Data type selection
37F3h
37F2h
[Ao1] monitor bias adjustment Cd-23
37F4h
37F3h
[Ao1] monitor gain adjustment Cd-24
Output level setting at [Ao1]
37F5h
37F4h
monitor adjust mode
Filter time constant of [Ao2]
37FBh
37FAh
monitor
37FCh
37FBh
[Ao2] Data type selection
37FDh
37FCh
[Ao2] monitor bias adjustment Cd-33
37Feh
37FDh
[Ao2] monitor gain adjustment Cd-34
Output level setting at [Ao2]
37FFh
37FEh
monitor adjust mode
High-function General-purpose Inverter RX2 Series User's Manual
Parameter
Function name
No.
CC-56
CC-57
CC-58
CC-59
CC-60
Cd-01
Cd-02
Cd-03
Cd-10
Cd-11
Cd-12
Cd-13
Cd-14
Cd-15
Cd-21
Cd-22
Cd-25
Cd-31
Cd-32
Cd-35
9 Communications Functions
R/W
Monitor or setting data
See <List of output terminal func-
R/W
tions> 062: LOG1 to 068: LOG7
cannot be selected.
00:AND
R/W
01:OR
02:XOR
See <List of output terminal func-
R/W
tions> 062: LOG1 to 068: LOG7
cannot be selected.
See <List of output terminal func-
R/W
tions> 062: LOG1 to 068: LOG7
cannot be selected.
00:AND
R/W
01:OR
02:XOR
00: PWM
R/W
01: frequency
R/W
0 to 3600
See the List of output monitor
R/W
*1
functions
See the List of output monitor
R/W
*1
functions
See the List of output monitor
R/W
*1
functions
00: Disabled
R/W
01: Enabled
R/W
1 to 500
00: absolute value
R/W
01: with sign
R/W
-1000 to 1000
R/W
-10000 to 10000
R/W
-1000 to 1000
R/W
1 to 500
00: absolute value
R/W
01: with sign
R/W
-1000 to 1000
R/W
-10000 to 10000
R/W
-1000 to 1000
R/W
1 to 500
00: absolute value
R/W
01: with sign
R/W
-1000 to 1000
R/W
-10000 to 10000
R/W
-1000 to 1000
Resolution
-
-
-
-
-
-
1(Hz)
1
1
1
-
1(ms)
-
0.1(%)
0.1(%)
0.1(%)
9
1(ms)
-
0.1(%)
0.1(%)
0.1(%)
1(ms)
-
0.1(%)
0.1(%)
0.1(%)