Omron RX2 Series User Manual page 855

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

Monitors for Checking Internal Condition
Code
dC-01
Inverter load type selection monitor
dC-02
Rated current monitor
Speed command destination moni-
dC-07
tor (main)
Speed command destination moni-
dC-08
tor (auxiliary)
Operation command destination
dC-10
monitor
dC-15
Cooling fin temperature monitor
dC-16
Life diagnostic monitor
dC-20
Total start-up count
dC-21
Power-on count
Cumulative operating hours monitor
dC-22
during RUN
dC-24
Cumulative power-on time
Cumulative operating time of cooling
dC-26
fan
dC-37
Detailed monitor for icon 2LIM
dC-38
Detailed monitor for icon 2ALT
dC-39
Detailed monitor for icon 2RETRY
dC-40
Detailed monitor for icon 2NRDY
High-function General-purpose Inverter RX2 Series User's Manual
Name
00 (very low duty)/01 (low duty/02 (normal duty)
0.0 to 6553.5 (A)
00 (disabled)/01 (Ai1)/02 (Ai2)/03 (Ai3)/04 (Reserved)/
05 (Reserved)/06 (Reserved)/07 (Multistage speed 0)/
08 (auxiliary speed)/09 (Multistage speed 1)/
10 (Multistage speed 2)/11 (Multistage speed 3)/
12 (Multistage speed 4)/13 (Multistage speed 5)/
14 (Multistage speed 6)/15 (Multistage speed 7)/
16 (Multistage speed 8)/17 (Multistage speed 9)/
18 (Multistage speed 10)/19 (Multistage speed 11)/
20 (Multistage speed 12)/21 (Multistage speed 13)/
22 (Multistage speed 14)/23 (Multistage speed 15)/
24 (JG)/25 (RS485)/26 (Option 1)/27 (Option 2)/
28 (Option 3)/29 (Pulse array (main unit))/
30 (Pulse array (Option))/31 (DriveProgramming)/
32 (PID)/33 (Reserved)/34 (AHD retention speed)
00 ([FW]/[RV] terminal)/01 (3 wire)/
02 (RUN key on operator keypad)/03 (RS485 setting)/
04 (Option 1)/05 (Option 2)/06 (Option 3)
-20.0 to 200.0 (°C)
LL to HH [L: normal/H: reduction of life]
[Left side ] (FAN life)
(lives of the capacitors on the circuit board) [Right side]
1 to 65535 (Counts)
1 to 65535 (Counts)
1 to 1000000 (hr)
1 to 1000000 (hr)
1 to 1000000 (hr)
00 (Condition other than below)/
01 (Overcurrent suppression in process)/
02 (Overload being limited)/
03 (Overvoltage suppression in process)/
04 (Torque being limited)/
05 (Upper/lower limit and jump frequency setting being lim-
ited)/
06 (Setting of minimum frequency being limited)
00 (Condition other than below)/
01 (Overload advance notice)/
02 (Motor thermal advance notice)/
03 (Controller thermal advance notice)/
04 (Motor overheat advance notice)
00 (Condition other than below)/
01 (Retry standby)/02 (Restart standby)
00 (Preparation completed condition other than below
IRDY=OFF)/
01 (Trip occurred)/02 (Power supply abnormality)/
03 (Resetting)/04 (STO)/05 (Standby)/
06 (Data inconsistency Others (including no FB, consistency
of settings of A and B phases, etc.))/
07 (Sequence abnormality)/08 (Free run)/
09 (Forced stop)
Appendices C Table of Parameters
Data range
C
C - 7