Replace The Hydraulic Tank Breather Cap - Models With Optional Hydraulic Oil - Genie GS-2669 RT Service Manual

Hide thumbs Also See for GS-2669 RT:
Table of Contents

Advertisement

Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
2 Tag, plug and remove the fuel lines from the
side of the tank.
3 Loosen the tank strap retaining fastener in front
of the tank. Move the strap off to the side.
4 Remove the tank from the machine.
5 Tag and remove the fuel fittings from the fuel
tank.
Note: Note the orientation of the fuel fittings before
removing so when the fittings are installed they will
be in the correct position.
6 Rinse out the inside of the tank using a mild
solvent.
7 Install the fittings (removed in step 5) into the
side of the tank.
8 Install the tank onto the machine.
9 Attach the fuel lines to the tank. Tighten the
clamps.
10 Secure the tank with the tank strap. Tighten the
retaining fastener. Do not over tighten.
3 - 32
GS-2669 RT • GS-3369 RT • GS-4069 RT
C-4
Replace the Hydraulic Tank
Breather Cap - Models with
Optional Hydraulic Oil
Genie requires that this procedure be performed
every 500 hours or six months, whichever comes
first.
The hydraulic tank is a vented-type tank. The
breather cap has an internal air filter that can
become clogged or deteriorate. If the breather cap
is faulty or improperly installed, impurities can enter
the hydraulic system which may cause component
damage. Extremely dirty conditions may require
that the cap be inspected more often.
1 Remove and discard the hydraulic tank breather
cap.
2 Install and new cap onto the tank.
November 2014
Part No. 229753

Hide quick links: