November 2014
Bleed the fuel system:
Note: Before bleeding the system, fill the fuel tank.
5 Loosen the vent plug/screw located on the filter
head.
6 Operate the hand primer until fuel, free of air,
flows from the vent plug/screw. Tighten the vent
plug/screw on the filter head.
7 Loosen the vent screw, located on top of the
fuel injection pump.
8 Operate the hand primer until fuel, free of air,
flows from the vent plug/screw. Tighten the vent
plug/screw on the injection pump.
9 Clean up any fuel that may have spilled.
10 Attempt to start the engine using the starter
motor for a maximum of 15 seconds, resting the
starter for 30 seconds before trying again.
11 Inspect the fuel filter/water separator for leaks.
Explosion and fire hazard. If a fuel
leak is discovered, keep any
additional personnel from entering
the area and do not operate the
machine. Repair the leak
immediately.
Note: Information to perform this procedure is also
available in the
Kubota D1105 Operator's Manual
(Kubota part number 16622-89166) OR the
Kubota D1105 Operator's Manual
Genie part number
Part No. 229753
131379
GS-2669 RT • GS-3369 RT • GS-4069 RT
Section 3 • Scheduled Maintenance Procedures
CHECKLIST A PROCEDURES
A-14
Perform Engine Maintenance -
Kubota Diesel Models
Engine specifications require that this procedure be
performed every one or two months.
• Recharge battery
Required maintenance procedures and additional
engine information is available in the
Kubota D1105 Operator's Manual
(Kubota part number 16622-89166).
Kubota D1105 Operator's Manual
Genie part number
131379