Section 5 • Fault Codes
FAULT CODE CHART
Error Source
ID
Name
69
Low Engine RPM N/A
70
High Engine RPM N/A
80
Left Front
Outrigger Coil
81
Left Rear
Outrigger Coil
82
Right Front
Outrigger Coil
83
Right Rear
Outrigger Coil
84
Outrigger Extend
Coil
85
Outrigger Retract
Coil
86
Float Coil
94
Machine Type
5 - 8
Error Type
ID
Name
Engine rpm
to low.
Engine rpm
to high.
N/A
Left front outrigger Left front outrigger
coil (Y35) fault.
N/A
Left rear outrigger Left rear outrigger
coil (Y33) fault.
N/A
Right front
outrigger coil
(Y36) fault.
N/A
Right rear
outrigger coil
(Y34) fault.
N/A
Outrigger extend
coil (Y40) fault.
N/A
Outrigger retract
coil (Y39) fault.
N/A
Oscillate float coil Elevated drive and
(Y95) fault.
N/A
Incorrect model
configuration
selected.
GS-2669 RT • GS-3369 RT • GS-4069 RT
Condition
Engine shutdown.
Engine shutdown.
disabled.
disabled.
Right front outrigger
disabled.
Right front outrigger
disabled.
Outrigger extend
function disabled.
Outrigger retract
function disabled.
platform up disabled. wiring.
Machine will not
operate.
November 2014
Solution
Adjust engine rpm.
Adjust engine rpm.
Troubleshoot coil or
wiring.
Troubleshoot coil or
wiring.
Troubleshoot coil or
wiring.
Troubleshoot coil or
wiring.
Troubleshoot coil or
wiring.
Troubleshoot coil or
wiring.
Troubleshoot coil or
Select correct model
configuration.
Part No. 229753