Clean The Fuel Tank - Diesel Models - Genie GS-2669 RT Service Manual

Hide thumbs Also See for GS-2669 RT:
Table of Contents

Advertisement

November 2014
Check the Down Limit Switch
Height
1 Turn the key switch to platform controls. Start
the engine.
2 Raise the platform approximately 10 ft / 3 m.
3 Lower the platform until the down limit switch
activates and the platform stops lowering.
4 Push in the red Emergency Stop button to the
off position.
5 Measure the distance between the working
surface and the platform deck.
GS-2669 RT
GS-3369 RT
GS-4069 RT
Part No. 229753
63 to 69 inches
1.6 to 1.75 m
66 to 72 inches
1.7 to 1.83 m
76 to 82 inches
1.9 to 2.1 m
GS-2669 RT • GS-3369 RT • GS-4069 RT
Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
C-3
Clean the Fuel Tank -
Diesel Models
Genie requires that this procedure be performed
every 500 hours or six months, whichever comes
first.
Removing sediment from the fuel tank is essential
to good engine performance and service life. A
dirty fuel tank may cause the fuel filter to clog
prematurely resulting in poor engine performance
and possible component damage.
Explosion and fire hazard. Engine
fuels are combustible. Clean the
fuel tank in an open, well-ventilated
area away from heater, sparks,
flames and lighted tobacco.
Always have an approved fire
extinguisher within easy reach.
Note: Immediately clean up any fuel that may have
spilled during this procedure.
1 Using an approved hand-operated pump, drain
the fuel tank into a suitable container. Refer to
Section 2, Specifications , for tank capacity.
Explosion and fire hazard. When
transferring fuel, connect a
grounding wire between the
machine and pump or container.
Note: Be sure to only use a hand operated pump
suitable for use with gasoline and/or diesel fuel.
3 - 31