Section 5 • Fault Codes
FAULT CODE CHART
Error Source
ID
Name
28
Drive Joystick
Off Neutral
29
Platform Up
Switch
30
Lift Joystick
Off Neutral
31
Platform Choke
Switch
32
Platform Start
Switch
33
Left Front
Outrigger Switch
34
Right Front
Outrigger Switch
35
Left Rear
Outrigger Switch
36
Right Rear
Outrigger Switch
5 - 4
Error Type
ID
Name
N/A
Drive joystick off
neutral when
machine is
powered on.
N/A
Platform up enable Platform up
button fault at
platform controls.
N/A
Up / Down switch Up / Down function
off neutral.
N/A
Starting aid fault at Starting aid
platform controls. disabled.
N/A
Engine start buttonEngine will not
fault at platform
controls.
N/A
Left front outrigger Outriggers disabled.
enable button fault,
platform controls.
N/A
Right front
outrigger enable
button fault,
platform controls.
N/A
Left rear outrigger Outriggers disabled.
enable button fault,
platform controls.
N/A
Right rear
outrigger enable
button fault,
platform controls.
GS-2669 RT • GS-3369 RT • GS-4069 RT
Condition
Machine functions
disabled.
function disabled.
disabled.
start.
Outriggers disabled.
Outriggers disabled.
November 2014
Solution
Release joystick
before power up or
replace joystick.
Troubleshoot button or
replace circuit board
at platform controls.
Replace up / down
switch at platform.
Troubleshoot button or
replace circuit board
at platform controls.
Troubleshoot button or
replace circuit board
at platform controls.
Troubleshoot button or
replace circuit board
at platform controls.
Troubleshoot button or
replace circuit board
at platform controls.
Troubleshoot button or
replace circuit board
at platform controls.
Troubleshoot button or
replace circuit board
at platform controls.