7-1

Auxiliary Platform Lowering

Auxiliary Platform Lowering
In the event of a main power failure, activating the
function enable and manual platform lowering
buttons at the ground controls will lower the
platform. There is no adjustment required.
The auxiliary platform lowering circuit uses the
main 12V DC battery for its power source.
Part No. 229753
GS-2669 RT • GS-3369 RT • GS-4069 RT
Section 4 • Repair Procedures

Ground Controls

7-2

Function Speed Tuning

All machine function speeds are determined by the
percentage of total ECM voltage output. The
speeds of the following machine functions may be
adjusted to compensate for wear in the hydraulic
pump and drive motors.
• Stowed drive speed
• High torque drive speed
• Raised drive speed
• Platform lift speed
For further information or assistance, consult the
Genie Industries Service Department.
Tip-over hazard. Do not adjust the
lift and/or drive speed higher than
specified in this procedure. Setting
drive speed greater than
specifications could cause the
machine to tip over resulting in
death or serious injury.
Tip-over hazard. This procedure
must only be performed by a
trained service professional.
Attempting this procedure without
the necessary skills will result in
death or serious injury.
How to Determine the Revision
Level
1 Turn the key switch to ground controls and pull
out the red Emergency Stop buttons to the on
position at both platform and ground controls.
Result: The revision level of the ECM will
appear in the LED display window.