Section 3 • Scheduled Maintenance Procedures
CHECKLIST A PROCEDURES
A-6

Inspect the Engine Air Filter

Genie specifications require that this procedure be
performed every 40 hours or weekly, whichever
comes first.
Maintaining the engine air filter in good condition is
essential to good engine performance and service
life. Failure to perform this procedure can lead to
poor engine performance and component damage.
1 Kubota WG972 models: Remove the engine
tray flange nut, located under the radiator on the
engine pivot tray. Swing the engine pivot tray
out and away from the machine for access.
2 Kubota D1105 models: Remove the wing nut
securing the end cap to the air cleaner canister.
Remove the end cap.
All other models: Disconnect the retaining
clamps securing the end cap to the air cleaner
canister. Remove the end cap.
3 Remove the air filter element.
4 Clean the inside of the air filter canister and the
canister gasket with a damp cloth.
5 Inspect for and remove any blockage or debris
from the intake air passages.
6 Inspect the air filter element. If needed, blow
from the inside out using low pressure dry
compressed air, or carefully tap out dust.
3 - 10
GS-2669 RT • GS-3369 RT • GS-4069 RT
7 Securely install the filter element into the
canister.
8 Install the gasket and baffle (if equipped), and
end cap onto the air cleaner canister.
Note: Be sure the dust discharge valve is facing
down when installed.
9 Secure the end cap to the air cleaner cannister
with the retaining clamps.
10 Kubota WG972 models: Swing the engine pivot
tray back to its original position and secure with
the flange nut.