November 2014
How to Prime the Pump
Component damage hazard. Be
sure that the hydraulic tank shut
off valves (if equipped) are in the
open position before priming the
pump. The engine must not be
started with the hydraulic tank shut
off valves in the closed position or
component damage will occur.
1 Turn the key switch to ground controls and pull
out the red Emergency Stop buttons to the on
position at both the ground and platform
controls.
2 Gasoline/LPG models: Disconnect the ignition
coil wire from the center of the ignition coil.
Diesel models: Hold the manual fuel shut off
lever clockwise in the closed position.
3 Crank the engine with the starter motor for
15 seconds, wait 15 seconds, then crank the
engine an additional 15 seconds.
4 Start the engine from the ground controls and
check for hydraulic leaks.
Part No. 229753