Genie GS-2669 RT Service Manual page 114

Hide thumbs Also See for GS-2669 RT:
Table of Contents

Advertisement

Section 4 • Repair Procedures
GROUND CONTROLS
1 Remove the platform controls from the platform.
If you are not installing a new level sensor,
proceed to step 7.
2 Locate the level sensor in the ground controls
compartment.
a
a
ground control box
b
level sensor
3 Tag and disconnect the wire harness from the
level sensor.
4 Remove the retaining fasteners securing the
level sensor to the compartment. Remove the
level sensor from the machine.
4 - 44
b
GS-2669 RT • GS-3369 RT • GS-4069 RT
5 Install the new level sensor onto the machine
with the "X" on the level sensor base towards
the steer end of the machine. Install and tighten
the level sensor retaining fasteners.
Tip-over hazard. The tilt level
sensor must be installed with the
"X" on the level sensor base
towards the steer end of the
machine. Failure to install the tilt
level sensor as instructed could
result in the machine tipping over
causing death or serious injury.
6 Connect the wire harness to the level sensor.
7 Turn the key switch to platform control and pull
out the red Emergency Stop buttons to the on
position at both the ground and platform
controls.
8 Set a multimeter to read DC voltage.
Adjust the side-to-side axis:
9 Without disconnecting the wire harness from the
level sensor, connect the negative lead of the
multimeter to the black wire at the level sensor.
10 Without disconnecting the wire harness from the
level sensor, connect the positive lead of the
multimeter to the yellow wire at the level sensor.
November 2014
Part No. 229753