7.4.1
Configuration
The following information is provided in the "Configuration" window:
Figure 7-4
● Drive object assignment
Display of the drive object number for existing drives.
● Drive groups
Display of the drive group for existing drives.
● F-DI discrepancy time
The signal states at the two terminals of an F-DI are monitored in order to determine whether
these have assumed the same logical state within the discrepancy time.
● TM54F safety sampling time
The displayed safety sampling time corresponds to the sampling time of the TM54F.
● F-DI input filter
Display of the parameterization of the debounce time of the F-DIs and single-channel DIs
of the TM54F. The debounce time specifies the maximum time an interference pulse can
be present at F-DIs before being interpreted as a switching operation.
● F-DI selection
– Display of the acknowledgment of safety alarms (assigned F-DI terminal pair).
– Display of the set retraction logic for SLP.