Terminal Module Tm54F - Siemens SINAMICS S120 Commissioning Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

LED
Color
Z pulses
Red
Green
3.1.4.6

Terminal Module TM54F

Table 3- 48
Meaning of the LEDs on the Terminal Module TM54F
LED
Color
READY
-
Green
Orange
Red
Green/red
Green/orange
or
Red/orange
L1+, L2+,
Red
L3+
Red
Fail-safe inputs / double inputs
F_DI z
LED
LED
(input x,
x
x+1
(x+1)+,
Red
(x+1)-)
Commissioning Manual
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
Status
Off
Zero mark found; wait for zero marker output; OR
component switched off.
Continuous
Zero mark not enabled or zero mark search.
light
Continuous
Stopped at zero mark.
light
Flashing light
Zero mark is output at each virtual revolution.
Status
Off
Continuous
light
Continuous
light
Continuous
light
0.5 Hz flashing
light
2 Hz flashing
light
Flashing light
ON
Continuous
light
ON
Continuous
light
Continuous
light
Description, cause
Description, cause
Electronics power supply is missing or outside the
permissible tolerance range.
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
DRIVE-CLiQ communication is being established.
At least one fault is present in this component.
Note:
The LED is activated irrespective of whether the
corresponding messages have been reconfigured.
Firmware is being downloaded.
Firmware download is complete. Wait for POWER ON
Component recognition via LED is activated (p0154).
Note:
Both options depend on the LED status when
component recognition is activated via p0154 = 1.
The controllable sensor power supply is functioning
fault-free.
There is a fault in the controllable sensor power supply.
Sensor power supply is functioning fault-free.
There is a fault in the sensor power supply.
NC contact / NC contact
1)
Different signal states at input x and x+1
No signal at input x and no signal at input x+1
NC contact / NO contact
1)
3.1 Diagnostics via LEDs
: (z = 0..9, x = 0, 2, ..18)
: (z = 0..9, x = 0, 2, ..18)
Diagnostics
Remedy
Remedy
Remedy and
acknowledge
fault
Carry out a
POWER ON
271

Advertisement

Table of Contents
loading

Table of Contents