Commissioning - drive-based
3.9 Safety Integrated functions
Settings
You can only make one setting in this window:
Figure 3-11
● Safe brake control (p9602)
The safe brake control can be enabled or inhibited using this selection list. This selection
list is deactivated if a motor holding brake is not included in the configuration (p1215).
For the following parameters, the status symbols indicate the actual state (blue = active; gray
= inactive):
● STO selected (r9773.0)
Setting "STO selected in drive select"
● Safe brake control active (r9773.4)
Setting "SBC requested"
● Closed brake selected (r0899.13)
Setting "Close command holding brake"
Parameter list
When required, alternatively you can use a parameter list for each setting in this window. You
can access the parameter list (Page 56) using the ">>" softkey followed by the "Parameter list"
softkey.
76
Safe brake control - SBC
Function Manual, 10/2015, 6FC5397-3EP40-5BA3