Commissioning - TM54F

4.1

Introduction

The TM54F Terminal Module is a terminal expansion board. The TM54F provides fail-safe
digital inputs and outputs for controlling the safety functions. Each Control Unit can be assigned
exactly one TM54F, which is connected via DRIVE-CLiQ. The TM54F provides 4 fail-safe
digital outputs and 10 fail-safe digital inputs. A fail-safe digital output consists of an output
switching to 24 V DC, an output switching to ground and a digital input for reading back the
switching state. A fail-safe digital input comprises 2 digital inputs.
Commissioning mode
The parameterization of a terminal extension module TM54F is displayed in 4 windows, and
can be modified there in the commissioning mode:
● Configuration (Page 103)
● Inputs (Page 105)
● Outputs (Page 106)
● Drive groups (Page 108)
Figure 4-1
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
TM54F in the view mode
4