● NC/NO contact
Display of the terminal property F-DI 0-9 (p10040.0 = F-DI 0, ..., p10040.9 = F-DI 9).
An NC contact is always connected to digital input 1 (upper). Digital input 2 indicates
whether an NC or NO contact has been selected.
● Testing F-DIs
Using a checkmark at an F-DI, it is displayed as to whether for the particular F-DI a forced
checking procedure of the sensor power supply should be carried out.
● Status symbol
The status symbol after the AND logic element indicates the following state:
– red = discrepancy error at this F-DI
– yellow = discrepancy error at another F-DI
– gray = inactive
– blue = active
7.4.3

Outputs

The output terminals of the actual TM54F are shown in the the "Outputs" window. This involves
the following terminals:
● X523
● X525
● X533
● X535
These terminals are on the front side of the module. The terminals are displayed one above
the other in the window.
You can reach the lower terminals by scrolling (page up/page down). Alternatively, using the
"Select terminal" softkey, you can open a selection and select the terminal that is to be
displayed in the window.
The following information is provided in the "Outputs" window:
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
Diagnostics
7.4 TM54F