9. Then evaluate the test result. Check the list as to whether all of the expected alarms have
occurred, and whether the results in the trace recording are correct.
Using the selection box at the lower right in the detailed display, define as to whether the
test (in this particular case: the switch-off signal paths) was successful.
Figure 5-9
The test name is allocated a green checkmark if the test was evaluated to be positive. In
this case, you can either perform another test in the active setting area - or as is normally
the case, you can initiate the next test via the next setting area.
If the test was evaluated to be negative, then the test name is assigned a red cross and if
necessary, you can repeat the test.
10.When required, correct the standard test names.
11.Press the "Next Test" softkey if you wish to start a test in the following setting area.
A test is created in the next setting area. A list of the necessary activities for this particular
test type is shown in the detailed display.
12.Follow the instructions on the screen (generally these involve steps 4 to 11).
After all tests of the individual setting areas have been performed, at the end, the "Finished"
setting area is displayed. In this setting area, you can generate the acceptance report from
the acceptance test and save it.
Other functions that can be called using softkeys
● Full screen
Hides the list of the setting areas and displays the detail settings of the currently selected
setting area over the complete screen width.
● Load template
Loads a template (XML format), which was created on a predecessor machine.
● Export template
Exports the current acceptance test as template (in the XML format). The template contains
a list of all of the possible tests that must be carried out for the acceptance test. Further,
all of the texts of the complete acceptance test are included; e.g. details about the machine
on the overview page.
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
Evaluating the acceptance test
Commissioning - acceptance tests
5.3 Sequence of an acceptance test