Commissioning - acceptance tests
5.3 Sequence of an acceptance test
"Switch-off signal path" setting area
You can test the switch-off signal paths in the "Switch-off signal path" setting area. Follow the
instructions in the detailed display.
Figure 5-2
You can make the following settings here:
● Define a test name
● Enter conditions to initiate the test
● Select acquired alarms that should appear in the report
● Confirm a test result
"Functional relationship" setting area
A function table serves as basis for the function composition test. Example:
Door open, "Setup" mode and
agreement button pressed
In the test, for each machine state, a check is made as to whether the spindle and feed axes
transition into the safety state as defined in the function table.
122
Switch-off signal path setting area
Machine state
Door closed and locked
Door open
Safety state of the spindle, MSP1
SLS4
STO
STO
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
Safety state of the feed axes,
MX1, MY1, MZ1
SLS4
SOS
SLS2