7.2
Safety Integrated diagnostics overview
The following signal information is displayed in the "Safety Integrated diagnostics overview"
window.
Figure 7-1
● General
– Safety operating mode (which operating mode is set)
– Number of safety NC axes
– Number of safety PLC axes
● Status
– SI alarms (which alarms are active)
You can call 4 basic diagnostic overviews from the diagnostic overview:
● SI drives
● TM54F
● SI checksums
● SI alarms
To do this, use the softkeys in the vertical softkey bar.
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
Diagnostics: Status overview
7.2 Safety Integrated diagnostics overview
Diagnostics
163