Commissioning - acceptance tests
5.1 Introduction
Authorized person, acceptance report
The test of each SI function must be carried out by an authorized person and logged in the
acceptance report. The report must be signed by the person who carried out the acceptance
tests. The acceptance report must be kept in the logbook of the relevant machine.
Authorized in this sense refers to a person who has the necessary technical training and
knowledge of the safety functions and is authorized by the machine manufacturer to carry out
the test.
Documentation, data archiving
The results of the acceptance test as well as all hardware and software changes according to
Table 5-1 Effects of the acceptance test (Page 116)must be documented in a suitable form.
In addition to the acceptance report, the drive parameters must be archived as SI-relevant
data.
Necessity of an acceptance test
A complete acceptance test is required when commissioning Safety Integrated functionality
on a machine for the first time (see Content of the complete acceptance test (Page 115)).
Extended safety-related functionality, transferring the commissioned software to additional
series machines, modifications to the hardware, software upgrades, changes within the scope
of modular machine concepts etc. make it necessary to carry out the acceptance test - possibly
with a reduced test scope.
In order to define a partial acceptance test, it is first necessary to describe the individual parts
of the acceptance test and then define logical groups that represent the components of the
acceptance test. The assignment of the safety-relevant machine data and parameters to
difference CRCs support this grouping (e.g. to support modular machine concepts).