Commissioning - TM54F
4.4 Exit the commissioning mode
Alternatively: 2b.
100
2a.
Objective: Only confirm data
If you do not wish to copy the SI data from the master to the slave, then
proceed as follows:
Press the "Confirm SI data" softkey.
As a consequence, the SI data of the actual TM54F are confirmed, and
the commissioning mode is exited.
- OR -
Press the "Confirm all TM54F" softkey.
As a consequence, the SI data of all TM54F is confirmed and the com‐
missioning mode is then exited.
This softkey is only visible if there are several TM54F devices are in your
drive system.
- OR -
Press the "Reset (po)" softkey.
This means that all changes to the SI data are undone. The NCK and the
complete drive system is then restarted.
Objective: Confirm the data and copy from the TM54F master to the
TM54F slave
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
Safety Integrated